iMeter D7 Advanced Power Quality Monitor


Device Introduction

  • iMeter D7 is CET’s Advanced DIN-Rail Mount PQ Analyzer designed for the compliance monitoring market as it offers un-surpassed functionality by combining Class 0.2S accuracy and advanced PQ features in a compact 145*124*77mm housing with a High-Resolution, IPS Color Dot-Matrix Display. The iMeter D7 complies with such standards as IEC62053-22 Class 0.2S, IEC61000-4-30 Ed.3 Class A, IEC61000-4-15, IEC61000-4-7, EN50160, IEEE Std 519-2022 as well as IEC61850 for Substation Automation.
    Further, it offers a large logging capacity with 4GB of on-board memory, extensive I/O, multiple Time Sync. methods, 2x100BaseT Ethernet and 1xRS-485 ports. In addition, it optionally supports wireless connection, 2xAI for measuring external transducer signal or 1xIresidual Input & 1xRTD for Leakage Current and Temperature Measurements. These features likely make the iMeter D7 the most advanced DIN-Rail PQ Analyzer for an intelligent Power QualityMonitoring System.

Product Highlight

  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed. 3.1 Class A Certified
  • 35mm DIN Rail Mount (145x124x77mm)
  • Colour IPS Dot-Matrix Display
  • Harmonics, Demands & TOU, PQ Log, Energy Log, Max/Min Log, Waveform Log and Event Log
  • 4GB On-board Memory
  • 2-150kHz Conducted Emission, MQTT
  • Modbus RTU, Modbus TCP, HTTPS, SNTP, SMTPS, FTP, IEEE1588 (PTP), IPSecVPN, MQTT, Ethernet Gateway, IEC61850
  • 2xEthernet, 1xRS-485, Optional built-in 4G modem
  • 4xDI, Optional 3xDO, 3xSS, 2xAI, 1xIr, 1xRTD

Typical Application

  • PQ monitoring at LV Utility Substations
  • Data Centers, Semiconductor Fabs, Heavy Industries
  • 7x24 Automated Manufacturing Facilities
  • Mains and Critical Feeder Monitoring
  • Renewable Energy Applications
  • Dips, Swells, Interruptions, Transients, Flickers and Harmonics monitoring
  • IEC 61850 support for Substation Automation and Smart Grid
  • Retrofit applications with optional Class 1 Split-Core Current Probes

Related Products

iMeter 5 Advanced Power Quality Monitor
iMeter 6 Advanced Power Quality Monitor
iMeter 7A Advanced Power Quality Monitor
iMeter 8 Advanced Power Quality Monitor

Specification

Technical Specification

VoltageInputs(V1,V2,V3,VN,V4,V4N) ****
Standard Un
400VLN/690VLL+20%
Range
5V to 2Un for 400VLN nominal
Overload
2xUn continuous,4xUn for 1s
Burden
<0.5VA/per phase
PT Ratio
  Primary
  Secondary
  V4 Primary
  V4 Secondary


1 to 1,000,000
1 to 1,500
1 to 1,000,000
1 to 1,500
Measurement Category
CAT III 1000V
Frequency
40Hz-60Hz@50Hz,48Hz-72Hz@60Hz
Current Inputs(·I11,I12,·I21,I22,·I31,I32,·I41,I42)
Standard In
5A(Standard),1A(Optional)
Range
1% to 400% In
Starting Current
0.1% In
Overload
4xIn continuous,10xIn for 1s
Burden
<0.5VA/per phase @ 5A
<0.1VA/per phase @ 1A
CT Ratio
  Primary
  Secondary
  I4 Primary
  I4 Secondary

1 to 30,000
1 to 50
1 to 30,000
1 to 50
SCCP Options
  SCCP-50A-500mV
  SCCP-200A-200mV
  SCCP-500A-500mV
  SCCP-5000-500mV
Split-Core Current Probe Input @ max. 500mV
5A/50A (In/Imax), max. 500mV Output
20A/200A (In/Imax), max. 200mV Output
500A Imax, max. 500mV Output
Selectable 500A/5000A (Imax) Rogowski Coil, max. 500mV Output
SCCT Options
PMC-SCCT-100A-40mA-16-A, Ø=16mm, Class 0.5
PMC-SCCT-200A-40mA-24-A, Ø=24mm, Class 0.5
PMC-SCCT-400A-40mA-35-A, Ø=35mm, Class 0.5
PMC-SCCT-800A-40mA-A, 80x50mm, Class 0.5
PMC-SCCT-1600A-40mA-A, 130x55mm, Class 0.5
SCCTA Option
PMC-SCCT-5A-2mA-16-A,Ø=16mm, Class 1
Power Supply(L+,N-)
Standard
95-250VAC/VDC ± 10%, 47-440 Hz
Optional
20-60VDC
Burden
< 14VA/10W @ 250VAC/DC
<6W @ 24VDC
Overvoltage Category
OVC III 300V
Digital Inputs(DIC,DI1,DI2,DI3,DI4,DIC2,DI5,DI6,DI7,DI8)
Type
Dry contact,24VDC internally wetted
Sampling
1000Hz
Hysteresis
1ms minimum
Digital Outputs(DO11,DO12,DO21,DO22,DO31,DO32,DO41,DO42)
Type
Form A Mechanical Relay
Loading
5A@250VAC or 30VDC
Alarm Output(Alarm)
Loading
5A @ 250VAC or 30VDC
Optional Solid State Pulse Outputs(E1+,E1-,E2+,E2-)
Type
Form A Solid State Relay
Isolation
Optical *****
Environmental Conditions
Operating Temp.
-25 °C to + 70°C
Storage Temp.
-40 °C to + 85°C
Humidity
5% to 95% non-condensing
Atmospheric Pressure
70 kPa to 106 kPa
Altitude
<2000m
Location/Mounting
For indoor use only
Mechanical Characteristics
Panel Cutout
92x92mm(3.62”x3.62”)
Unit Dimensions
96x96x88mm
IP Rating
IP65
Communications
Protocol
Modbus RTU, BACnet MS/TP, Metasys N2 and DNP3.0
RS-485 Port
1+(1 Opt.)
Features Summary
Display (Backlit)
Dot-Matrix LCD (Backlit)
Type of Measurement
ULN per Phase &Avg.
ULL per Phase&Avg.
Current per Phase &Avg.
Neutral Current (Meas./Calc.)
Frequency
kW per Phase & Total
kvar per Phase & Total
kVA per Phase& Total
PF per Phase& Total
kWh lmport/Export
kvarh Import/Export
kVAh Total
Power Quality
THD Voltage & Current
TOHD Voltage & Current
TEHD Voltage & Current
2nd-31st Harmonics
K-Factor
Voltage/Current Unbalance
Battery-backed Real-time Clock
√
Demands
Present , Predicted Demands and Max.Demands for This Month & Last Month
Multi-Tariff TOU capability
Two TOU schedules, each providing:
12 Seasons
90 Holidays
20 Daily Profiles, each with 12 Periods in 15-minute interval
8 Tariffs
Diagnostics
√
Setpoints
9 Setpoints
Logs
Max./Min.Log
This month & Last Month
Freeze Logs(Optional)
60 Daily Freeze Logs, 36 Monthly Freeze Logs
Data Recorder(Optional)
5 Data Recorders
Max. Recording Depth @ 10000 records
SOE Log
100 entries
On-board Log Memory
(4MB Opt.)

Accuracy

ParametersAccuracy
Resolution
Voltage±0.2%
0.001V
Current±0.2%
0.001A
I4(measurement)±0.2%
0.001A
P,Q,S±0.5%
0.001kx
kWh,kVAhIEC 62053-22 Class 0.5S
ANSI C12.20 Class 0.2
EN 50470-1/3:2006 Class C
0.1kXh
kvarhIEC 62053-24 Class 0.5S
IEC 62053-23 Class 2
0.1kvarh
PF±0.5%
0.001
Frequency±0.02Hz
0.01Hz
THDIEC 61000-4-7 Class B
0.001%
K-FactorIEC 61000-4-7 Class B
0.001
Phase Angle±1°
0.1°

Standards of Compliance

Safety Requirements
CE LVD 2014/35/EU
EN 61010-1: 2010
EN 61010-2-030: 2010
Electrical Safety in Low Voltage Distribution Systems up to 1000Vac and 1500Vdc
IEC 61557-12:2018(PMD)
Insulation
AC Voltage: 2kV@1 minute
Insulation Resistance: >100MΩ
Impulse Voltage: 6kV,1.2/50µs
IEC 62052-31:2015
Electromagnetic Compatibility CE EMC Directive 2014/30/EU(EN 61326:2013)
Immunity Tests
Electrostatic Discharge
EN 61000-4-2:2009
Radiated Fields
EN 61000-4-3:2006+A1:2008+A2:2010
Fast Transients
EN 61000-4-4:2012
Surges
EN 61000-4-5:2014+A1:2017
Conducted Disturbances
EN 61000-4-6:2014
Magnetic Fields
EN 61000-4-8:2010
Voltage Dips and Interruptions
EN 61000-4-11:2004+A1:2017
Ring Waves
EN 61000-4-12:2017
Emission Tests
Limits and Methods of Measurement of Electromagnetic Disturbance Characteristics of Industrial,Scientific and Medical(ISM) Radio-Frequency Equipment
EN 55011:2016
Limits and Methods of measurement of Radio Disturbance Characteristics of Information Technology Equipment
EN 55032:2015
Limits for Harmonic Current Emissions for Equipment with Rated Current≤16A
EN 61000-3-2:2014
Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems for Equipment with Rated Current≤16A
EN 61000-3-3:2013
Emission Standard for Residential, Commercial and Light-Industrial Environments
EN 61000-6-4:2007+A1:2011
RED (Radio Equipment Directive)
Assessment of Electronic and Electrical Equipment Related to Human Exposure Restrictions for Electromagnetic Fields (0Hz - 300 GHz)
EN/IEC 62311: 2020
Short Range Devices (SRD) Operating in the Frequency Range 25 MHz to 1000MHz
ETSI EN 300 220-1V3.1.1: 2017
ETSI EN 300 220-2 V3.1.1: 2017
Audio/Video, Information and Communication Technology Equipment -Part 1: Safety Requirements
IEC 62368-1: 2018
Mechanical Tests
Spring Hammer Test
IEC 62052-11:2003
Vibration Test
IEC 62052-11:2003
Shock Test
IEC 62052-11:2003

Wiring Mode

Wiring Mode
3P4W
3-Phase 4-Wire Wye Direct Connection with 3CTs
3-Phase 4-Wire Wye Direct Connection with 4CTs
3-Phase 4-Wire Wye with 3PTs and 3CTs
3-Phase 4-Wire Wye with 3PTs and 4CTs 
3P3W
3-Phase 3-Wire Direct Delta Connection With 3CTs
3-Phase 3-Wire Direct Delta Connection with 2CTs
3-Phase 3-Wire Delta with 2PTs and 3CTs
3-Phase 3-Wire Delta with 2PTs and 2CTs
1P3W
1-Phase 3-Wire Direct Connection with 2CTs
1P2W L-N
1-Phase 2-Wire, Uln Direct Connection with 1CT
1P2W L-L
1-Phase 2-Wire, Ull Direct Connection with 1CT